N2 - The evaluation of glassy carbon (GC) electrodes modified with a Nafion (Nf) film and doped with nanoalloys (Nys) deposits of Ag–Hg and Ag–Bi and their application to determination of Cd (II) and Pb(II) in marine sediments, is described. Deposited Ag–Hg and AgBi Nys have a size of approximately ~80 nm dispersed and embedded inside the booths of the Nf net, while other of them remained on Nf net surface. For the AgBiNysNf-GC electrode, a detection limit (DL), 3 s criterion, slightly higher than for the AgHgNysNf-GC modified electrode was obtained. Accuracy of measurements was asserted by comparison with quantification of Cd and Pb in three sets of marine sediments samples previously analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES). The values of the standard deviation and the coefficients of variation are very low, and also comparable between the different determinations.
AB - The evaluation of glassy carbon (GC) electrodes modified with a Nafion (Nf) film and doped with nanoalloys (Nys) deposits of Ag–Hg and Ag–Bi and their application to determination of Cd (II) and Pb(II) in marine sediments, is described. Deposited Ag–Hg and AgBi Nys have a size of approximately ~80 nm dispersed and embedded inside the booths of the Nf net, while other of them remained on Nf net surface. For the AgBiNysNf-GC electrode, a detection limit (DL), 3 s criterion, slightly higher than for the AgHgNysNf-GC modified electrode was obtained. Accuracy of measurements was asserted by comparison with quantification of Cd and Pb in three sets of marine sediments samples previously analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES). The values of the standard deviation and the coefficients of variation are very low, and also comparable between the different determinations.
KW - Bimetallic nanoparticles
KW - ICP-OES spectroscopy
KW - Modified electrodes
KW - Pb and Cd anodic stripping voltammetry
UR - http://www.scopus.com/inward/record.url?scp=85106926571&partnerID=8YFLogxK
U2 - 10.1016/j.heliyon.2021.e07120
DO - 10.1016/j.heliyon.2021.e07120
M3 - Article
AN - SCOPUS:85106926571
SN - 2405-8440
VL - 7
JO - Heliyon
JF - Heliyon
IS - 5
M1 - e07120
ER -