Legionnaires' disease prevention in water cooling systems

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

The water cooling systems are one of the main sources of growth of the bacteria Legionella. Southern Spain (Autonomous Community of Andalusia, Malaga) offers industrial and tourist sites with highrisk devices and a large influx of people. The analysis of the degree of control and water disinfection is presented as a preventive indicator against the development of the biological agent, included in national legislation. Through a descriptive study and use of nonparametric tests, is concluded that regulation compliance is higher in the studied systems than in other facilities at risk. There are deficiencies in preventive maintenance of the devices water quality, so there is a serious risk to the exposed population.

Translated title of the contributionPrevención de la legionelosis en sistemas de refrigeración de agua
Original languageEnglish
Pages (from-to)9-17
Number of pages9
JournalDYNA (Colombia)
Volume78
Issue number165
StatePublished - 2011
Externally publishedYes

Keywords

  • Control
  • Disinfection
  • Legionnaires'disease
  • Water cooling systems